>>measure gas consumption of a small boiler, an individual furnace...etc.
.Flow-rate range (m3/h) : 6-60、12.5-150、30-300
.Max. working Pressure (kPa) : 350 or 980 (3.5 or 9.9kgf/cm2)
.Accuracy : ±1%FS and ±3%RS(Flow measurement section)
.High accuracy consists with the light-weighted compact stylish body
.Temperature/pressure compensation function (Selective)
.Free installation position |
|
| |
|
|
|
|
|
>>measure gas consumption of a small boiler, an individual furnace...etc.
.Flow-rate range (m3/h) :4-30、10-100、12.5-150
.Max. working Pressure (kPa) : 100kPa (Approx. 1.0kgf/cm2)
.Accuracy : ±1%FS
.High accuracy consists with the light-weighted compact stylish body
.Temperature/pressure compensation function (Selective)
.Free installation position
|
|
| |
|
|
|
|
|
>>Ultrasonic Flow meter For Air
.Robust against oilmist and dust
.Turndown ratio 50:1
.Ultrasonic sensor is integrated
.Negligible pressure drop (equivalent to straight pipe)
.Easy to read LCD which can be oriented at a right angle for easy viewing
.2 outputs for easy integration with other system
.Lower cost than vortex flowmeters or clamp - on type flowmeters
|
|
| |
|
|
|
 |
Picture |
Model |
Describe |
certification |
|
|
>>For Liquid Measurement/Can measure pure water
.Flow range:0.6-30 to 4-200 m3/h
.High durability with no moving parts
.Turndown ratio 50:1
.Ultrasonic sensor is integrated
.Negligible pressure drop (equivalent to straight pipe)
.Easy to read LCD which can be oriented at a right angle for easy viewing
.2 outputs for easy integration with other system |
|
| |
|
|
|
|
|
>>Compatible with various kinds of fluids
.Flow range:0.3 ~ 3 to 3 ~ 60 L/min
.Highly accurate over a wide measurement range
.Simple and durable structure,Compact and lightweight
.Free installation position,Excellent cost-performance
.High sensitive high-density pulse output
.for measuring variety of fluid and outputs open collector pulses with the built-in amplifier type magnetic sensor. |
|
| |
|
|
|
|
|
>>Instantaneous / Flow-rate·Integrating / Measurement of various liquids
.Flow range:0.3~3 / 1.5~20 / 3~60 L/min
.Built-in lithium batteries (No external power supply is required)
.Revolving display unit (It can be fixed to a easy-to-read position)
.Simplified structure with the vane wheel type measuring principle
.Value holding function for Instantaneous Flow-Rate indication
.Pulse output function (Option)
|
|
| |
|
|
|
|
|
>>Oval gear type flow sensor
.Flow-rate range (±1% RS):0.5 ~ 50 to 5 ~ 300 L/h
.Accuracy : ±2% RS
.Measurable fluid:light oil, heavy oil, and cold water, as well as for chemicals
.Compact and lightweight,the connection was designed to facilitate easy installation in any system layout.
|
|
| |
|
|
|
|
|
>>Oval gear type/Instantaneous Flow-Rate·Integrating Flow Volume Flowmeter
.Flow-rate
range (m3/h) : 0.0085 ~ 0.85 to 0.7 ~ 5 L/min
.Accuracy : ±2%RS±0.007L/min , ±2% RS±0.04L/min
.Measurable fluid:light oil, heavy oil, and cold water, as well as for chemicals
.Compact and lightweight,the connection was designed to facilitate easy installation in any system layou |
|
| |
|
|
|
 |
Picture |
Model |
Describe |
certification |
|
|
>>Small Electromagnetic Flow Sensor
.Flow-rate range : 0.05~1 / 0.5~10 / 3~60 L/min
.Measure fluid : Sodium hypochlorite、Sodium hydroxide aqueous solution
.Compact and excellent cost performance
.Outstanding reliability with no moving parts
.Suitable for use in machines , Easy-to-check 2-color LED(status) indicator
.2 selectable outputs (Unitpulse,High-density pulse,Warning,Switch) |
|
| |
|
|
|
|
|
>>Small Electromagnetic Flow Sensor
.Flow-rate range : 0.05~1 / 0.5~10 / 3~60 L/min
.Measure fluid : Liquid which does not corrode materials that contact the liquid,
Not less than electric conductivity rate 50μS/cm
.Compact and excellent cost performance
.Outstanding reliability with no moving parts
.Suitable for use in machines , Easy-to-check 2-color LED(status) indicator
.2 selectable outputs (Unitpulse,High-density pulse,Warning,Switch) |
|
| |
|
|
|
|
|
>>Small-Size Flow Sensor
.Flow-rate range : 1 ~ 10 L/min
.Accuracy:within ± 7 % (RS)
.Measurable fluid : City water
.Maximum working pressure : Up to 0.75 MPa (At fluid temprature of 20°C)
.Superior repeatability,Low pressure drop
.Simple structure,Free installation position,Small and light weight |
|
| |
|
|
|
 |
Picture |
Model |
Describe |
certification |
|
|
>>Adjustable Flow Indicator
.Measuring Range(L/min Di H2O):0.2~1 to 30~90
.Measuring Range(L/min Air):6~30 to 900~2700
.Output:4~20mA、0-10V
.Maximum load:48VAC-1A、48VDC-0.5A
.minimum distance of 30 mm from inductive
magnet fields and ferrous parts |
|
|
|
|
|
|
|
>>Electronic Flow Indicator
.Measuring Range(L/min Di H2O):0~4/0~10/0~20
.Measuring Range(L/min Air):0~120/0~300/0~600
.Accuracy:<±5%end of scale ±3 digit (at 20℃)
.Maximum load:48VAC-1A、48VDC-0.5A
.Hysteresis value: adjustable for all scale
.Display: 3 digit
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
| |
|
|
|