WELCOME TO JETEC
 
 
contact
message
Contact us
 
Product
Tempertaure Controller

■TTM-J4/J5

Non-contact Temp.Measurement

>>Infrared Thermometers
■JDIT-130
■JDIT-500
■PyroUSB
■PyroCouple

>>Infrared Thermal Imager
■JKT-160
■MikroShot

Humi & Temp Data logger

>>Internal Sensor
■JS300-TH
■JS320-TH
>>External Sensor
■JS300-EX
■JS320-EX
>>USB Data logger
■JHE-173

H/T Transmitter
■JW300
Level Sensor / Meter

>>Ulrtasonic
■ULM-70
■ULM-53
>>Hydrostatic
■JTK-620
■HLM-25S
■HLM-16/25
>>Capacitive
■CLS-23
■DLS-27
■CLM-36
■HBS
>>Level Switch
■CLS-53N
■FLD-48
■GPLS-25
>>Position/Displacement Sensor
■HBP

Flow Sensor / Meter

>>For Air
■TBZ
■TBX
■TRX
>>For Liquid Measurement
■TRL
■ND
■NW
■OF-Z
■OF-W
>>Small-Size Flow Sensor
■VNS
■VN
■NDV10
>>Flow Indicator
■ZV
■ZVL

wireless Transmission Module

■JWL
■EE240
>>Base Station
■FLTA
■RYFL
>>Repeater
■FLREP
■FLREP-U
>>Wireless Transmitter
■TEFL
■TEFL-RH
■TEUFL
■KLUFL
■HDHFL
■HDHFL-RH
>>Commissioning Tool
■FLSER

Wireless Weather Sensor
>>Soil moisture / temperature
■JSMHP
>>Soil pH
■JASP2801
>>Rain Gauge
■JTB
■RG200
Pressure Sensor
■JPT-131
Gas(Co / CO2)

>>CO Detector
■JCD-10M
■HML
>>CO2 Detector
■JCD-30 Series
■JCO-8 Series
■KCD-HP
■EE82
■KCD-DA
■HDU
■HDH
■EE80
■HDK
■EE85
>>GAS Detector
■JDA-50 Series
>>Smoke Detector
■JSD-50
■JHT
■JSB

Measurement Instruments

>>Clamp-On Meters
■JCMP-200
■JCMP-400/401
■JCMP-1006

 
About Jetec
ITEM >>>
Turbine Gas Meter
Picture
Model
Describe
certification
Turbine Gas Meter
>>measure gas consumption of a small boiler, an individual furnace...etc.
.Flow-rate range (m3/h) : 6-60、12.5-150、30-300
.Max. working Pressure (kPa) : 350 or 980 (3.5 or 9.9kgf/cm2)
.Accuracy : ±1%FS and ±3%RS(Flow measurement section)

.High accuracy consists with the light-weighted compact stylish body
.Temperature/pressure compensation function (Selective)
.Free installation position
CE
     
Turbine Gas Meter
>>measure gas consumption of a small boiler, an individual furnace...etc.
.Flow-rate range (m3/h) :4-30、10-100、12.5-150
.Max. working Pressure (kPa) : 100kPa (Approx. 1.0kgf/cm2)
.Accuracy : ±1%FS
.High accuracy consists with the light-weighted compact stylish body
.Temperature/pressure compensation function (Selective)
.Free installation position

CE
     
Ultrasnoic Flow Meter
>>Ultrasonic Flow meter For Air
.Robust against oilmist and dust
.Turndown ratio 50:1
.Ultrasonic sensor is integrated
.Negligible pressure drop (equivalent to straight pipe)
.Easy to read LCD which can be oriented at a right angle for easy viewing
.2 outputs for easy integration with other system
.Lower cost than vortex flowmeters or clamp - on type flowmeters

CE
       
Flow Sensor / Flow Meter
Picture
Model
Describe
certification
Ultrasnoic Flow Meter
>>For Liquid Measurement/Can measure pure water
.Flow range:0.6-30 to 4-200 m3/h
High durability with no moving parts
Turndown ratio 50:1
Ultrasonic sensor is integrated
Negligible pressure drop (equivalent to straight pipe)
Easy to read LCD which can be oriented at a right angle for easy viewing
2 outputs for easy integration with other system
CE
     
Flow Sensor
>>Compatible with various kinds of fluids
.Flow range:0.3 ~ 3 to 3 ~ 60 L/min
.Highly accurate over a wide measurement range
.Simple and durable structure,Compact and lightweight
.Free installation position,Excellent cost-performance
.High sensitive high-density pulse output
.for measuring variety of fluid and outputs open collector pulses with the built-in amplifier type magnetic sensor.
CE
     
Flow Sensor With Indicators
>>Instantaneous / Flow-rate·Integrating / Measurement of various liquids
.Flow range:0.3~3 / 1.5~20 / 3~60 L/min
.Built-in lithium batteries (No external power supply is required)
.Revolving display unit (It can be fixed to a easy-to-read position)
.Simplified structure with the vane wheel type measuring principle
.Value holding function for Instantaneous Flow-Rate indication
.Pulse output function (Option)
CE
     
Microstream Flow Sensor
>>Oval gear type flow sensor
.Flow-rate range (±1% RS):0.5 ~ 50 to 5 ~ 300 L/h
.Accuracy : ±2% RS
.Measurable fluid:light oil, heavy oil, and cold water, as well as for chemicals
.Compact and lightweight,the connection was designed to facilitate easy installation in any system layout.
CE
     
Microstream Flow Sensor
>>Oval gear type/Instantaneous Flow-Rate·Integrating Flow Volume Flowmeter
.Flow-rate range (m3/h) : 0.0085 ~ 0.85 to 0.7 ~ 5 L/min
.Accuracy : ±2%RS±0.007L/min , ±2% RS±0.04L/min
.Measurable fluid:light oil, heavy oil, and cold water, as well as for chemicals
.Compact and lightweight,the connection was designed to facilitate easy installation in any system layou
CE
       
SmallL-Size Flow Sensor
Picture
Model
Describe
certification
Small Electromagnetic Flow Sensor
>>Small Electromagnetic Flow Sensor
.Flow-rate range : 0.05~1 / 0.5~10 / 3~60 L/min
Measure fluid : Sodium hypochlorite、Sodium hydroxide aqueous solution
.Compact and excellent cost performance
.Outstanding reliability with no moving parts
.Suitable for use in machines , Easy-to-check 2-color LED(status) indicator
.2 selectable outputs (Unitpulse,High-density pulse,Warning,Switch)
CE
     
Small Electromagnetic Flow Sensor
>>Small Electromagnetic Flow Sensor
.Flow-rate range : 0.05~1 / 0.5~10 / 3~60 L/min
.Measure fluid : Liquid which does not corrode materials that contact the liquid, Not less than electric conductivity rate 50μS/cm
.Compact and excellent cost performance
.Outstanding reliability with no moving parts
.Suitable for use in machines , Easy-to-check 2-color LED(status) indicator
.2 selectable outputs (Unitpulse,High-density pulse,Warning,Switch)
CE
     
SmallL-Size Flow Sensor
>>Small-Size Flow Sensor
.Flow-rate range : 1 ~ 10 L/min
.Accuracy:within ± 7 % (RS)
.Measurable fluid : City water
.Maximum working pressure : Up to 0.75 MPa (At fluid temprature of 20°C)
.Superior repeatability,Low pressure drop
.Simple structure,Free installation position,Small and light weight
CE
       
Capacitive Level Sensor
Picture
Model
Describe
certification
Adjustable Flow Indicator
>>Adjustable Flow Indicator
.Measuring Range(L/min Di H2O):0.2~1 to 30~90
.Measuring Range(L/min Air):6~30 to 900~2700
.Output:4~20mA、0-10V
.Maximum load:48VAC-1A、48VDC-0.5A
.minimum distance of 30 mm from inductive magnet fields and ferrous parts
 
     
ELECTRONIC FLOW INDICATOR
>>Electronic Flow Indicator
.Measuring Range(L/min Di H2O):0~4/0~10/0~20
.Measuring Range(L/min Air):0~120/0~300/0~600
.Accuracy:<±5%end of scale ±3 digit (at 20℃)
.Maximum load:48VAC-1A、48VDC-0.5A
.Hysteresis value: adjustable for all scale
.Display: 3 digit

 
       
       
 
Page 2-Flow sensor
 
       