Picture |
Model |
Describe |
certification |
|
|
>>Wall mounting CO detector
.Measuring principle : Electro-chemical
.Sampling method : Diffused
.Measurement range : 0~500ppm
.Accuracy : ±3% / full scale
.Output Signal: 4~20mA, two spdt relay-contact(AL1 / AL2) |
|
| |
|
|
|
|
|
>>HAVC / Wall mounting
.Measurement Range:0~100 or 0~300 ppm
.Output Signal:0~10V or 4~20mA
.Time constant (t63%) 1,5 min
.Supply:24 Vac/dc 2W (22 Vac/dc… 28 Vac/dc)
.Operating temp.:-30~40℃
.Protection:IP54 |
|
|
|
|
|
 |
Picture |
Model |
Describe |
certification |
|
|
>>Duct mounting / Wall mounting CO2 detector
.Measuring principle : NDIR(Non-Depressive Infrared)
.Duct air velocity : 0 ~ 450 meter/min
.Measurement range:0 ~ 2,000PPM / 0 ~ 5,000PPM
.Accuracy:±3% / full scale
.Output:Analog 4 ~ 20mA, two spdt relay-contact(AL1 / AL2) |
|
| |
|
|
|
|
|
>>Wall mounting CO2 detector
.Sensor Type : NDIR (Non-dispersive Infrared)
.Measurement Range:0~3,000ppm
.Accuracy:±75 ppm or ±5% of reading of reading whichever is greater
.Repeatability : ±20 ppm @400ppm
.Three different LED display show the current Indoor Air Quality situation.
.Voltage(0~10V) ,Current Loop and Relay output. |
|
| |
|
|
|
|
|
>>Excellent stability and accuracy
.Sensing Method : Dual Wavelength NDIR
.Measurement Range:0~1,000 to 0~200,000 ppm (Options)
.Accuracy:±(3%F.S.+2%Reading)
.Output:0~5V, 0~10V, 4~20mA、
.Communication Output :RS485
.Response Time:< 65 sec |
|
| |
|
|
|
|
|
>>CO2 transmitter for demanding applications
.Measuring principle : NDIR(Non-Depressive Infrared)
.Measurement Range:0...2000 / 5000 / 10000ppm
.Output:0...5V / 10V or 4...20mA
.Supply : 24V AC/DC
.Applications : green houses、fruit and vegetable storage、life stock barns
.easy installation、auto-calibration、compact housing |
|
| |
|
|
|
|
|
>>Wall mounting / CO2 Controller
.Sensing Method : Dual Wavelength NDIR
.Measuring
range:0~2000, 0~5000, 0~10000 ppm / -10~60℃ / :0~99%RH
.Outputs:0-10V/4-20mA
.Accuracy:±(40ppm+3% reading)、±2℃、±3%
.Communication:RS485、Relay SPST(only CO2)
.Response time:CO2: < 30 sec、temp/humi:< 10 sec
.Operating Conditions:CO2:5~45℃、temp/humi:-10~60℃ |
|
| |
|
|
|
|
|
>>CO2 Transmitter For Cold Spaces
.Measuring
range:0~2000 ppm / -50~50℃
.Accuracy : ± 40 ppm +3% from value , ±0,8°C
.Long term stability / year : < 2% FS (ABCLogic™)
.Temperature dependence : 0.2% FS / °C
.Output : 0 -10V < 2 mA
.The CO2 sensor will become self-calibrated regularly by using patented ABCLogic™ method. |
|
| |
|
|
|
|
|
>>Wall mounting / CO2 Transmitter -Controller
.Measuring
range:0~2000 ppm / 0~50℃ / 0~100 %rH
.Time constant (t 63%) : 0.2% FS / °C
.Long term stability / year : < 2% FS (ABCLogic™)
.Output :0~10V
.The CO2 sensor will become self-calibrated regularly by using patented ABCLogic™ method. |
|
| |
|
|
|
|
|
>>Wall mounting / CO2 indoor transmitter
.Measuring
range:0~2000 ppm, 0~5000ppm / 10~90%RH / -5~55℃
.Accuracy : +/-50ppm + 2% of measuring value; +/-3% RH; +/-0.3 °C
.Outputs:0...5V / 10V; 4...20mA
.Supply : 24V AC/DC
|
|
| |
|
|
|
|
|
>>Transmitter / - Controller For Duct
.Measuring
range:0~2000 ppm / 0~50℃
.Accuracy : ± 40 ppm +3% from value / ±0,5°C
.Long term stability / year : < 2% FS (ABCLogic™)
.Time constant (t 63%) : 0.2% FS / °C
.Outputs:0~10V
.The CO2 sensor will become self-calibrated regularly by using patented ABCLogic™ method. |
|
| |
|
|
|
|
|
>>CO2 transmitter for duct mounting
.Measuring
range:0...2000 / 5000 / 10000ppm; -20...60°C
.Outputs:0-5 / 10V; 4...20mA
.Response time (t 63%) : < 195s
.Long term stability : typ. 20ppm / year
|
|
|
|
|
|
 |
Picture |
Model |
Describe |
certification |
|
|
>>SMART-Gas Detector
.Detection Mechanism:NDIR:Non-Dispersive Infrared,PID(Photoionization)
.Input Power : DC 20~32V
.Accuracy : ± 3%/Full Scale
.Signal Output:4∼20mA、RS485
.Relay Output : 2Step-Relay(AL1,AL2) |
|
|
|
|
|
 |
Picture |
Model |
Describe |
certification |
|
|
>>Smoke Detector / Smoke Sensor
.Detection Principle:Ionization smoke chamber
.Detection Method :Diffusion type
.Response Time:within 3 sec.
.External Output:A contact (DC 30V 1A),B contact
.Operating Temperature/Humidity:-20~60°C、5~95%RH (Non-condensing) |
|
|
|
|
|
|
|
>>Stand Alone Smoke Detector
.Alarm sound: >=85db(3m)
.static current:<8uA
.alarm current:10mA
.Low voltage alarm:5.5V~6.2V
.Low battery alert remain: 7~15days
.Voltage : DC9V / AC110V or AC220V /DC9V & AC220V or DC9V & AC110V |
|
|
|
|
|
|
|
>>Stand Alone Smoke Detector
.Smoke Sensitivity:0.086 dB/m to 0.14 dB/m
.Power Supply:9V Carbon Zinc/Alkaline/Lithium Batttery
.Battery Life: >12months
.Low battery life: >30days
.Alarm indicator:continuously emitting red light and shounder
.Alarm sound level: >85dB at 10 feet (3m) |
|
| |
|
|
|
| |
|
|
| |
|
|
|